Compliance Matrix

 

To recieve a quote, please complete the following, and press "submit" at the bottom

Your Name
Your Company
Street Address
City
State
Zip Code
Phone
Facsimile
Email
System Type

 
ARE YOU IN COMPLIANCE ?
Inspection and Testing Quote, Select the Items below and press "submit"
 
Qtr
Semi
Ann
2yrs
3yrs
4yrs
5yrs
20yrs
 
Manual Pull Stations
X
 
NFPA 72
Smoke Detectors
X
 
NFPA 72
Heat Detectors (10% per year)
X
 
NFPA 72
Duct Smoke Detectors
X
 
NFPA 72
Fire Doors
X
 
NFPA 72
Air Handler (Fan Shut Down)
X
 
NFPA 72
Elevator Recall - Alternate Recall
X
 
NFPA 72
Auxillary Safety Functions    
X
         
NFPA 72

Fire Curtains

X
 
NFPA 72
Notification Devices
X
 
NFPA 72
Smoke Sensitivity (1st yr, Every other yr)
X
 
NFPA 72
Supervisory Tampers Inspection & Test
X
 
NFPA 72
Water Flow Test
X
 
NFPA 72
Quarterly Sprinkler Inspection
X
 
NFPA 25
Semi Annual Sprinkler Insp & Test
X
NFPA 72
Annual Sprinkler Flow Inspection &Test
X
 
NFPA 25
5 Year Sprinkler Inspection and Test
X
NFPA 25
Sprinkler Head Laboratory Test and replacement
 
X
NFPA25
Pre-Action Sprinkler System Flow Test
X
 
NFPA 72
Anti Freeze Solution
X
 
NFPA 25
Fire Damper Link Inspection& Test
X
 
NFPA 90
Fire Smoke Damper Inspection& Test
X
 
NFPA 90
Kitchen Hoods (Maintance)
X
 
NFPA 17-17A
Clean Agent Supression Systems Halon, Carbon Dioxide, FM200 Etc...
X
 

NFPA 12-12A

Annual Fire Pump Flow Test    
X
NFPA 25
Backflow Preventers  
X
NFPA 25
Fire Extinguisher Annual Inspection and Maintenance    
X
         
NFPA 10
Fire Hydrant Inspetion & Test  
X
NFPA 25
Emergency Exit Signs & Emergency Lighting
X
 
NFPA 101

 
Inpection, Testing and Maintenance of Stand Pipe Systems
Item Activity Frequency Description NFPA 25 Reference
1.1
I
Quarterly Control Valves 12.3.2.1
1.2
I
Quarterly Pressure Regulating Devices 12.5.2.1 12.5.3.1
1.3
I
Quarterly Back Flow Preventers 12.6.1
1.4
I
SemiAnnually Piping 12.3.2.1
1.5
I
SemiAnnually Hose Connections Chapter 12
1.6
I
SemiAnnually Cabinet NFPA 1962
1.7
I
SemiAnnually Hose NFPA 1962
1.8
I
SemiAnnually Hose Storage Device NFPA 1962
2.1
T
Annually Alarm Device (90 Seconds.) 12.2.7
2.2
T
Annually Hose Nozzle NFPA 1962
2.3
T
Annually Main Drain Test 12.2.6 12.3.3.4
2.4
T
Annually Control Valve - Position 12.3.3.1
2.5
T
Annually Control - Valve - Operation 12.3.3.1
2.6
T
Annually Supervisory 12.3.3.5
2.7
T
Annually Backflow Preventer Assemblies 12.6.2
2.8
T
Annually Pressure Reducing Valve - Partial Flow Test 12.5.23 12.5.3.3
2.9
T
5/3 Years Hose Hydrostatic Test NFPA 1962
2.10
T
5 years Hose Storage Device NFPA 1962
2.11
T
5 years Pressure Control Valve

12.5.2.2 12.5.3.2

2.12
T
5 years Pneumatic & Hydrostatic Test 6.3.2
2.13
T
5 years Flow Test 6.3.1
2.14
T
5 years Presure Reducing Valve 12.5.2.2 12.5.3.2
2.15
T
5 years Fire Department Connection Back flush 12.7.4
3.1
M
Annually Control Valves 12.3.4
3.2
M
Annually

Hose Connections

Table 6.2.2
3.3
M
Annually Valves (All Types) Chapter 12

 

 
Inpection, Testing and Maintenance of Water Storage Tanks
Item Activity Frequency Description NFPA 25 Reference
1.1
I
Daily/Weekly* Water Temperature 9.2.4
1.2
I
Daily/Weekly* Heating System 9.2.6.6
1.3
I
Monthly Temperatue Alams

9.2.4.2 9.2.4.3

1.4
I
Monthly/Quarterly Condition of Water in Tank 9.2.1
1.5
I
Monthly/Quarterly Water Level 9.2.1
1.6
I
Monthly/Quarterly Air Pressure 9.2.2
1.7
I
Quarterly Control Valves 12.3.2.1
1.8
I
Quarterly Tank - Exterior 9.2.5.1
1.9
I
Quarterly Support Structure 9.2.5.1
1.10
I
Quarterly Catwalks and Ladders 9.2.5.1
1.11
I
Quarterly Surrounding Area 9.2.5.2
1.12
I
Quarterly Hoops And Grillage 9.2.5.4
1.13
I
Quarterly Paint Coated Surfaces 9.2.5.6
1.14
I
Quarterly Expansion Joints 9.2.5.3
1.15
I
Quarterly Interior 9.2.6
1.16
I
Quarterly Check Valves 12.4.2.1
2.1
T
Monthly Temperature Alarms 9.2.4.2 9.2.4.2
2.2
T
Monthly High Temperature Limit Switch 9.3.4
2.3
T
SemiAnnually Water Level Alarms 9.3.5
2.4
T
Annually Control Valve - Position 12.3.3.1
2.5
T
Annually Control - Valve - Operation 12.3.3.1
2.6
T
Annually Supervisory 12.3.3.5
2.7
T
5 Years Level Indicators 9.3.1
2.8
T
5 Years Pressure Guages 9.3.6
2.9
T
5 Years Automatic Filling Device 9.3.7
3.1
M
SemiAnnually Drain Silt 9.4.5
3.2
M
Annually Control Valves 12.3.4
3.3
M
Annually Water Level 9.4.1
3.4
M
Annually Embankment-Supported Coated Frabric (ESCF) 9.4.6
3.5
M
Annually Check Valves 12.4.2.2

 

Please provide additional details below:

Email us !!